EATON 3MM512R12RLB 5-Jaw 5-Socket Multiple Metering Meter Stack Module With Ringless Style Cover and Horn Bypass, 120/208 V AC, 125 A, 3 Phase, NEMA 3R Enclosure
Cutler-Hammer Series 3MM512R12RLB
EATON 3MM512R12RLB 5-Jaw 5-Socket Multiple Metering Meter Stack Module With Ringless Style Cover and Horn Bypass, 120/208 V AC, 125 A, 3 Phase, NEMA 3R Enclosure
Non-stock product. Available to order - lead time may vary.
BrandCutler-Hammer Series
MFG #3MM512R12RLB
Werner Part #2370259
UPC782114786321
Non-stock product. Available to order - lead time may vary.
BrandCutler-Hammer Series
MFG #3MM512R12RLB
Werner Part #2370259
UPC782114786321
Product Description
EATON Meter Stack Module, 5-Jaw 5-Socket Multiple Metering, 120/208 V AC, 125 A, 3 ph, 100 kA Short Circuit, Bus Bar Connection, Plug-On Mounting, NEMA 3R Enclosure, 12.26 in L x 7.01 in W x 8 in D Dimensions
Attributes
Documents
Applications
Warranty
Features
Specifications
Attributes
Connection TypeBus Bar
Country of OriginUS
Dimensions12.26 in L x 7.01 in W x 8 in D
Enclosure TypeNEMA 3R
ManufacturerEaton
Package TypeEACH
Phase3
Short Circuit Current Rating100 kA
Suitable For Use WithPowerMark Gold Load Center and THQL Frame Circuit Breaker
Power Distribution, Outdoor, Residential and Facilities Applications
Warranty
1 year
Features
Meter socket and tenant main breaker or wireway sections are separated by a solid metal barrier to guard unmetered bus against power theft
A convenient termination for neutral conductors is in the wireway of each module
Enclosures are made of galvanized steel construction and include rust inhibiting phosphate primer and gray baked enamel for long term durability
Meter socket base is installed without any fasteners, reducing chances for hot spots
Separate covers allow easy access to tenant breaker and wireway section, permit work on breakers or in wireway without disturbing meters or meter covers
For use with BR2, BRH2, BRHH2 and BRX2, plug-on type main tenant breaker
Interrupt rating depends on selected main circuit breaker
3 mm stacks are 3-phases in, 1-phase OUT design
Short circuit ratings up to 100 A RMS symmetrical depending upon the kAIC rating of installed main tenant circuit breakers and main device
Mechanically and electrically built to bolt up with main service modules and residential modular metering stacks
All 3-phases horizontal bus modules have 4-wire cross bus, connected A-B phase to vertical bus, readily reconnectable for phase balance on installation
All 3 mm stacks include 5-jaws at 9 o'clock position