Appleton UNILETS EYF-75 Dust-Ignitionproof Explosionproof Raintight Conduit Sealing Fitting, 3/4 in, For Use With IMC/Threaded Rigid Metallic Conduit, Malleable Iron, Triple Coated
Appleton EYF-75
Appleton UNILETS EYF-75 Dust-Ignitionproof Explosionproof Raintight Conduit Sealing Fitting, 3/4 in, For Use With IMC/Threaded Rigid Metallic Conduit, Malleable Iron, Triple Coated
In Stock: 39more info
|
BrandAppleton
MFG #EYF-75
Werner Part #15836
UPC781381135122
In Stock: 39more info
|
BrandAppleton
MFG #EYF-75
Werner Part #15836
UPC781381135122
Product Description
Appleton UNILETS Conduit Sealing Fitting, Dust-Ignitionproof Explosionproof Raintight, Series: EY Series, 3/4 in, For Use With: IMC/Threaded Rigid Metallic Conduit, Malleable Iron, Triple Coated, 3.5 in L x 1.38 in W
Attributes
Documents
Applications
Features
Specifications
Warranty
Attributes
Country of OriginMX
Dimensions3.5 in L x 1.38 in W
FinishTriple Coated
GTIN00781381135122
ManufacturerEmerson Electric
MaterialMalleable Iron
Package TypeEACH
Size3/4 in
Suitable For Use WithIMC/Threaded Rigid Metallic Conduit
TypeDust-Ignitionproof Explosionproof Raintight
Type / StyleDust-Ignitionproof Explosionproof Raintight
For prevent passage of gases, vapors or flames from one portion of conduit system to another
Features
Smooth, rounded integral bushing in each hub to protect conductor insulation
Accurately tapped, tapered NPT threads for tight, rigid joints and ground continuity
Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub
Restrict any explosion to the sealed off enclosure
Required in Class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures
Required in Class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps
Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location
Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure
Required where cables which exceed rate of gas or vapor transmission permitted for seals are used in Class I, Division 2 locations
25% fill vertical and horizontal conduit sealing fittings for close turning radius
Standards & Approvals: UL 886|UL 1203 File No. E10444|CSA C22.2 No. 30|CSA 065181, Class I, Groups A, B, C, D, Class II, Groups E, F, G, Class III|RoHS Compliant